BKI2398: Kit, RLB for IFR 2398
|
|
Features: |
| Used with IFR2398 Spectrum Analyzer |
|
| Foam with cutouts included |
| High performance return loss bridge |
| Custom coaxial cables with port labels |
| Use for antenna/cable measurements |
| Use for reflection measurements |
| Precision termination and short |
| Two attenuators included |
|
|
Applications |
This kit is designed to compliment the IFR 2398 Spectrum Analyzer. Included are all components required to perform swept antenna and feedline measurements. The components are contained in a durable plastic case. This not only protects the components during transit from one job to another, but also helps prevent loss. |
To aid in hookup, the cables are labeled as to which port they connect to on the spectrum analyzer and return loss bridge. The connectors are also the correct ones so that no adapters are required. |
Description |
The case is 10 wide x 8 5/16 deep x 3 high. All of the components are supplied with the kit. |
The return loss bridge covers from 5.0 Mhz to 3000 Mhz. For more information see RLB150N5A specification sheet.
The precision termination and short are used to verify that the bridge is in calibration and to determine the open/short ratio before making your measurement. |
|
| to next Column |
 |
|
Description-continued |
Two six db attenuators are included. These are useful when making return loss measurements where most of the power is reflected (high return loss). In these types of measurements it is necessary to improve the open short ratio. Using the attenuators improves the port match which improves the open short ratio. |
The power splitter can be used for cable distance to fault measurements in conjunction with the 2398 and optional EasySpan software. |
Availability |
The parts that are supplied with these kits are normally in stock so a kit can be constructed within one week of order. |
 |
Specifications & Ordering |
Please see the next page for detailed specifications, performance graphs and ordering information. Refer to the price list on this site for pricing and terms for this product. |
 |
| to next Page |
|
 | |
 |  |
 |  |
Page 2 |  |
TABLE OF SUPPLIED COMPONENTS
|
| | | |
Return Loss Bridge | RLB150N5A | Bridge, 5-3000 Mhz 40 dB | VSWR and Return Loss |
Test Cable 1 | 128NMNM02R0 | Cable, 50 ohm, N(m)-N(m), 2.0' | Gen. out 2398 to SRC on RLB |
Test Cable 2 | 128NMNM02R0 | Cable, 50 ohm, N(m)-N(m), 2.0' | Anal. in 2398 to Ref. on RLB |
Termination | RFT050NM2 | Termination, 50 ohm, Precision | Directivity cal of bridge |
Short | RFT000NM1 | Termination, 0 ohm | Open/short cal of bridge |
Power Splitter | HPD123NF | Divider, Power DC-3.0 GHz | Use for cable fault test prog |
Attenuator | PFA060N | Attenuator 2W, 6 dB | Gen out to improve port match |
Attenuator | PFA060N | Attenuator 2W, 6 dB | Anal In to improve port match |
Case | 01 1231 000001 | Case, with foam padding | Carrying case for everything |
|
 |
SPECIFICATIONS |  |  |  |
Electrical: | Mechanical: |
 |  |  | Case Size: |
 | Refer to individual component |  |  | 10"W x 8 5/16" D x 3" H |
 | sheets for detailed specs |  | Weight: |
 |  |  |  | < 2.0 lbs |
|
 |  |