2.2.10BKG8000, Kit, RLB for GD R8000 .005-3.0 GHz

Features

  • Use with GD R8000 Analyzers
  • Components useable to >3.0 GHz
  • High directivity Return Loss Bridge
  • Custom coax. cables with port labels
  • Use for ant/feedline measurements
  • Use for reflection measurements
  • Precision termination and short
  • Rugged Case
  • Low Cost

Applications

This kit is designed to compliment the General Dynamics R8000 Communications System Analyzer. Included are all components required to perform swept antenna and feedline measurements including cable fault location. The kit is also useful for Duplexer/Diplexer verification and tuning.
The kit can also be used to measure overall system sensitivity which is useful to determine the loss thru the various system components. A precision termination and a precision short is provided to verify the bridge and power divider.

Description
The components supplied are contained in a durable plastic case. This case not only protects the components during transit from one job to another, but also helps prevent loss. The case is 10 wide x 8 5/16 deep x 3 high. All of the components shown are supplied with the kit.

The return loss bridge covers from 5.0 Mhz to 3000 Mhz. For more information see RLB150N4B specification sheet.
Two coaxial cables are provided to connect the bridge or power divider to the R8000. The cables are labeled as to which port they are connected to on the Communications Service Analyzer and return loss bridge. The cable connectors are also the correct ones so that no adapters are required.

to next Column

Description-continued

The precision termination, with >40 dB directivity to 3.0 GHz and 2 watt continuous power rating, and short are used to verify that the bridge is in calibration and to determine the open/short ratio before making your measurement.
A precision power divider is included. This unit covers from DC-3.0 GHz with excellent port match and directivity and has a power rating of 5 watts. This is intended for cable distance to fault measurements using the R8000's software.
Two Type 'N' 6 dB attenuators are included to reduce the effects of the hookup cables on the return loss bridges open/short ratio when doing cable loss measurements.

Availability

One week for small quantity orders or sooner.

Specifications & Ordering

Please see the next page for detailed specifications, performance graphs and ordering information. Refer to the price list on this site for pricing and terms for this product.

to next Page

TABLE OF SUPPLIED COMPONENTS

Item

Part No

Description

Use

Return Loss Bridge

RLB150N4B

Bridge, 5.0-3000 MHz

VSWR and Return Loss

Test Cable 1

128BMNM02R0

Cable, 50 ohm, BNC(m)-N(m), 2.0'

RF GEN OUT-SOURCE

Test Cable 2

128BMTM02R0

Cable, 50 ohm, BNC(m)-N(m), 2.0'

ANTENNA-REFLECTED

Termination

RFT050NM2

Termination, 50 ohm, Precision

Directivity cal of bridge

Short

RFT000NM1

Termination, 0 ohm

Open/short cal of bridge

Power Divider

HPD123NF

Divider, Power DC-3.0 GHz

Use for cable fault test prog.

Case

01 1231 000001

Case, with foam padding

Carrying case for everything

SPECIFICATIONS

Electrical

Mechanical

Refer to individual component sheets for detailed specifications.

Case Size:

10"W x 8 5/16" D x 3" H

Weight:

< 2.0 lbs

website: eagle-1st.com

email: use contact page

Phone: 928 204-2597

PO Box 579

fax: 928 204-2568

ClarkDale, AZ 86324

08 Dec 2009 css-a ΥΤΦ-8

06-Nov-2009 css-a ΥΤΦ-8 Crea3DS2 4.7

12210000

03/16/2010